Error Codes

B-xv

CTREE

CTREE is the database software used by PLC-500 A.I. to manage the documentation.

CTREE errors indicate problems with the documentation database. Many of these can

be corrected using the utility options.

2: CTREE_DUP_REC_ERROR

An attempt to write a duplicate record to the database has occurred! Symbol name may

be already in use!

ADDR: SYM:

This error indicates an attempt to create another record for an existing symbol, or a

second record for a particular address.

5: CTREE_OLDDBASE

Use the Update Database option from the Utility Options menu.

10: CTREE_SPAC_ERR

Not enough dynamic memory available to initialize data base.

Not enough RAM available to use the database system. See the section on memory

errors for details.

14: CTREE_CORRUPT_DATABASE

Data Base is corrupt and must be rebuilt.

Use the Rebuild Damaged Database option on the Utility Options menu.

16: CTREE_KCRAT_ERR

Could not create index file!

See the section on DOS errors for information on why creating a file might fail.

17: CTREE_DCRAT_ERR

Could not create data file!

See the section on DOS errors for information on why creating a file might fail.

37: CTREE_DBASE_WRITE_ERROR

Data Base write error - disk may be full!