Error Codes

B-xix

NETWORK_STAT_ERR

Status Error 80 - DIAGNOSTIC CODE:%d

Attempting to download a program larger than will fit in the available PLC memory.

The program is too large for the SLC 500 memory. You will have to reduce the size of

the program.

Program Error

Most of these errors indicate an ACH file which is damaged or created using some

other software package. In many cases, these errors warn you that PLC-500 A.I. is

attempting to correct the problem. Examine the ladder logic to see if the attempt

succeeded.

1: PROGRAM_ERROR_1

Attempting to program past end of program file. Addr=%u End of file=%u

2: PROGRAM_ERROR_2

Last instruction in program file incomplete, runs into next program file. Last rung will

be deleted. Curaddr=%u Next Start=%u

3: PROGRAM_ERROR_3

Invalid start of rung address encountered while copying rung to edit buffer.

4: PROGRAM_ERROR_4

Invalid edit. Instruction is off programming screen.

The rung involved is too large. Break it into smaller rungs, or increase the

Programming Screen Size parameters in the Program Operational Parameters screen.

5: PROGRAM_ERROR_5

Archived file header too long (%u bytes) - creating new header.

6: PROGRAM_ERROR_6

Invalid file header encountered - %u extra bytes in file not read

7: PROGRAM_ERROR_7

Last rung in Program File #%d has no output!

8: PROGRAM_ERROR_8

Program file too large to fit into buffer! File Number=%d length=%u