14-13

For the import utility to function properly, six APS files are required in the source

directory.

Data File

Contents

.AC$

Instruction descriptions

.B1$

Index

.IX$

Symbol descriptions

.OP$

Address information

.PC$

Rung Descriptions

.ACH

Ladder logic

During the import, when selecting the import file name, the File Selector lists files

ending in a .OP$ extension. If the APS software is on the same computer as your

PLC-500 A.I. software, the directory is typically C:\IPDS\ARCH\SLC500.

If database files already exist, the utility prompts you to confirm the import option. For

further confirmation, the utility displays a summary screen with the full path names for

both the source and destination directories.

As the import proceeds, the utility displays incoming description text for informational

purposes.