MicroLogix 1000 and PLC-500 A.I. Series Software Reference

16-8

Channel 0 Configuration Options

Description

Channel 0

Parameter

SLC 5/03 OS300

SLC 5/03 OS301 and up, and

SLC 5/04 OS400 and up

Current
Communication
Mode

Not available. This processor uses
System Mode.

Toggles between System and User.
The default is System.

System Mode
Driver

Toggles between DH-485 Master, DF1
Half-Duplex Slave, DF1 Full-Duplex,
and Shutdown. Default is DF1 Full-
Duplex.

Toggles between DH-485 Master, DF1
Half-Duplex Slave, DF1 Half-Duplex
Limited Master, DF1 Full-Duplex, and
Shutdown. Default is DF1 Full-Duplex.

User Mode Driver Not available.

Toggles between Generic ASCII and
Shutdown. The default is Generic
ASCII.

Write Protect

Toggles between Enabled and
Disabled. If Enabled, you will only be
able to monitor, not edit, ladder and
data table files online. The default is
Disabled.

Toggles between Enabled and
Disabled. If Enabled, you will only be
able to monitor, not edit, ladder and
data table files online. The default is
Disabled.

Mode Changes

Not available.

Enable or Disable remote mode
changes (via external device). The
default is Disabled.

Mode Attention
Character

Not available.

This character alerts the processor to a
remote mode change. Enter any
hexadecimal value or ASCII printable
character. The default is \0x1b (Esc).

System Mode
Character

Not available.

This character follows the Mode
Attention Character to tell the
processor to change to System Mode.
Enter any hexadecimal value or ASCII
printable character. The default is S.

User Mode
Character

Not available.

This character follows the Mode
Attention Character to tell the
processor to change to User Mode.
Enter any hexadecimal value or ASCII
printable character. The default is U.

Edit
Resource/File
Owner Timeout

This is the communication timeout
period (application layer). Valid range
is 1-65535 seconds. The default is 60.

This is the communication timeout
period (application layer). Valid range
is 1-65535 seconds. The default is 60.

Passthru Link ID

Not applicable

Valid range is 1-65534.