Monitoring binary files – Rockwell Automation 9323-S5500D A.I. SERIES MICROLOGIX 1000 AND PLC-500 SOFTW User Manual
Page 84

MicroLogix 1000 and PLC-500 A.I. Series Software Reference
4-16
!
Typing a value and then pressing a cursor key will cause the value to be entered in
the data table.
Monitoring Binary Files
When monitoring binary files, the file monitor screen appears as follows:
The following function keys are active on this screen:
[F1]
Radix
Allows you to change the display radix to the following options:
[F1]
Binary
[F2]
Integer
[F3]
BCD/Hex
[F4]
Ascii
[F5]
Octal
[F3]
Xref
(Available when displaying usage.) Displays the Cross Reference List
for the bit under the cursor.
[F5]
neWaddr
(Available when displaying values.) Allows you to enter a different
address to display.
[F6]
Des
Start the instruction description editor for the highlighted address
[F7]
Next
Display the monitor screen for the next data table file