Online editing modes – Rockwell Automation 9323-S5500D A.I. SERIES MICROLOGIX 1000 AND PLC-500 SOFTW User Manual

Page 413

Advertising
background image

Online Editing and Monitoring

18-3

Online Editing Modes

Note

Online editing is not available when the keyswitch is in the RUN position. If you

attempt to perform an online edit with the keyswitch in the RUN position, the message:

“Can’t acquire edit resource!”

is displayed.

The SLC 5/03 or 5/04 processor’s keyswitch position and mode determine the online

editing mode.

With

run mode online editing

, the user program is executing when an edit takes

place, and the keyswitch is in the REMote position. Any rungs that are inserted,

modified, or deleted remain in the ladder program and are indicated by edit zone

markers on the power rail. Edit zone markers remain after an action is completed.

Changes are not executed until you test the edits.

With

program mode online editing

, the user program is

not

executing when an

edit session begins, and the processor is in Program or REMote Program mode.

This mode is like the offline editing mode. Inserted or modified rungs are marked

with edit zones only until you accept the edits. Deleted rungs are removed rather

than marked. If you edit a rung that has edit zone markers from a previous

runtime online edit, the markers are removed when the rung is accepted.

The following table summarizes the SLC 5/03 and SLC 5/04 processor keyswitch

positions and modes which enable online editing. For additional information on

keyswitch positions for the SLC 5/03 and SLC 5/04 processors, refer to Allen-Bradley

publication

SLC 500 Modular Hardware Style Installation and Operation Manual

,

publication number 1747-6.2. For information on processor modes for the MicroLogix

processors, refer to Allen-Bradley publication

MicroLogix 1000 with Programming

Software User Manual

, publication number 1761-6.3.