MotionSuite™ Series Machine Controller Software Manual
Chapter 4: File Manager
4-76
Example 2: When the slot number is 3-04
a. Add slot numbers which are up to the rack of (rack number-1) (see Table 4.27).
3-1=2, then total slot number of rack 1 and rack 2 is:
Lock 1 (=14)+Rack 2 (=14)=28
b. Add (slot number+1) to the (a) result,
28+(4+1)=33
c. Since nn=33 according to (b), then the Transfer Definition File name is
$ESLOT33.
Note:
In the MP9xx, only rack 1 is short-fixed.
4.13.3 Individual Transfer
Individually designated programs or definition data can be transferred.
Table 4.27: Slot Number
Rack
Slot Number
Rack1~4
Long (single)
14
Long (dual)
12
Short (single)
8
3
2
1
4