Input/output assignment – Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 168
Advertising
MotionSuite™ Series Machine Controller Software Manual
Chapter 6: Module Configuration
6-24
Input/Output Assignment
(1)Setting the Assignment Data
In the Input/Output Assignment tab window, set up the data of input/output devices
to be connected to the network, or the transmission definition data.
1. Station Number
The station number is displayed. Up to 14 station can be set up.
2. Type
Set up the input/output devices to be connected to the stations. Select from the
combo-box menus.
3. Disable
Set up the input register disable status.
SGD-xxN
Servo amplifier
SGD-xxAN
Servo amplifier
JEPMC-IO350
IO350 remote I/O module
Enable status
Disable status
1
2
5
6
7
8
4
3
Advertising