Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 306

MotionSuite™ Series Machine Controller Software Manual
Chapter 8: Ladder Programming
8-58
• Error Window Structure
Compilation processing is executed when a program is saved. An error window is
displayed if a compilation error is detected.
1. Program type
The type of program where an error is detected is displayed.
2. Code
The code number of the error is displayed.
3. Error contents
The contents of the error are displayed.
4. Step 1
The number of the step where an error is detected is displayed in the case of a
main program or SFC program, while the number of the row where an error is
detected is displayed in the case of a list format program or Tuning Panel pro-
gram.
5. Step 2
The invalid data of the main program or SFC program is displayed. The number
of the column where an error is detected is displayed in the case of list format
program of Tuning Panel program.
6. Detail 1
This data is invalid on a list program or Tuning Panel program other than a main
program, SFC program, parameter list (#Register), or interlock list. A plural
number is displayed when an error is detected in the parameter list (#Register),
while a sub-number is displayed when an error is detected in the interlock list
creation screen.
7. Detail 2
This data is invalid on the current version.
1
2
3
8
7
6
5
4