3 annunciator signal configuration – Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 243

MotionSuite™ Series Machine Controller Software Manual
Chapter 7: System Data Definition
7-70
f. Comment Input
This function reads register comment data edited during main program creation,
and sets it into the Failure Name box.
f.1
Move the cursor to the Failure Name box of the relay for which comment
data is to be read out.
f.2
Select Comment (K) from Edit (E) in the Failures menu.
f.3
The register comment data is read out and displayed.
Note:
This function cannot be executed if a relay number has not been input into the Relay box,
or if no register comments have been created during main program creation. See Item
8.2.9, “Comment Creation” for more details on creating comments.
7.8.3
Annunciator Signal Configuration
Input register numbers to create annunciator circuits in the Annunciator tab. The fol-
lowing screen is displayed upon opening the fault monitor window and clicking the
Annunciator tab.
1. General Output
Input the general output coil number (fault M output, unconfirmed output, veri-
fied output). Input a bit register number for each output coil number. The input-
table register types are O and M registers.
2. Relay
This column displays the fault relay. Fault relays are set in the Failures tab.
1
2
3
4
5
6
7
8
9