MotionSuite™ Series Machine Controller Software Manual

Chapter 9: Motion Programming

9-4

1. Standardization Level

Input the DWG/Program rank using one character. The rank can be freely deter-
mined by the user.

2. File Privilege

Input the DWG/Function program read/write privileges. The privilege data can-
not be set to a value higher than that of the privilege of the present user.

3. D Register

Input the number of D register words when using a D register within a DWG/
Function program. If zero is input, D register reference within the program is
impossible. For example, if 10 is input, the usable D register numbers within the
program are as follows:

Integers: DW00000~DW00009
Double-length Integers: DL00000~DL00008
Real Numbers: DF00000~DF00008
Bits: DB000000~DB000009F

4. Parallel Processing

Set the maximum number of parallel processes, 0 to 4, using the PFORK com-
mand.

5. Program Data

This displays data related to motion control. It is for reference only and no
changes can be made.

Machine Type

Maximum Number of Parallel Processes

MP9xx

4