Yaskawa MotionSuite Series Machine Controller Software Manual User Manual
Page 230

MotionSuite™ Series Machine Controller Software Manual
Chapter 7: System Data Definition
7-57
3. Status
This displays the date and time of the latest data trace, and the execution status of
the data trace at that time.
RUN:
Trace under execution
STOP:
Trace stopped
4. Trace Time Axis
Displays trace data by axis type (for details, see Item 7.7.8 “Trace Time Axis
Change”).
SNOA:
Displays trace data in sample number units with the trace start time
at 0.
SNOB:
Displays trace data in sample number units with the trace stop time
at 0.
TIMEA: Displays trace data in time units with the trace start time at 0.
TIMEB:
Displays trace data in time units with the trace stop time at 0.
5. Data Name
The data names DATA-01, DATA-02, and DATA-03 are automatically attached
to the data to be traced.
6. Register Number
This column displays the register numbers to be traced.
7. Sample Number
This column displays the sample numbers. The display status differs according
to the Trace Time Axis box.
8. Trace Data
This column displays traced data in accordance with the register type (16-bit
integer, 32-bit integer, real number, bit)
9. Status
This displays the data trace execution status of the CPU in the currently dis-
played group.
Display Data Update
This function displays the newest trace data. Update the trace data display as follows:
a. Select Mode (M)
⇒RE-DSP(R) from View (V) in the data trace menu.
b. The newest trace data is displayed.