Yaskawa MotionSuite Series Machine Controller Software Manual User Manual

Page 235

Advertising
background image

MotionSuite™ Series Machine Controller Software Manual

Chapter 7: System Data Definition

7-62

4. Register Number

Select the 16-bit integer, 32-bit integer, or real number register number to be
traced. It is possible to select the register number set in the Trace Data Designa-
tion box of the Trace Definition tab. However, it is not possible to select register
numbers in the automatic update mode.

5. Scale Conversion

Input the scale conversion of the trace data. It is possible to adjust the vertical
amplitude of the graph by this value. When automatic update (see the subsec-
tion, “Display Data Update” in Item 7.7.8) is used, continuous display is done
using this value as the amplitude. The data set into the Trace Designation: Scale
box in the Trace Definition tab is set as the default. The amplitude is the same
when 0 is input as when 32767 is input.

6. Maximum Value

This displays the maximum value of trace data.

7. Minimum Value

This displays the minimum value of trace data.

8. Display ON/OFF Switching

Display may be switched alternately ON or OFF by selecting this button.

9. Relay Number

This displays the bit register number to be traced.

10. 16-bit Integer/32-bit Integer/Real Number Data Display

This displays 16-bit integer/32-bit integer/real number data in graph form. A
maximum of four data units can be displayed at once.

11. Bit Data Display

This displays bit data in graph form. A maximum of four data units can be dis-
played at once.

12. Current Execution Status

This displays the data trace execution status of the CPU in the group number cur-
rently displayed.

RUN:

Data trace execution underway

STOP:

Data trace stop

13. Scale Adjustment Slider

This adjusts the horizontal amplitude of the trace data displayed in the data dis-
play area by dragging the slider. This can also be adjusted by pushing the left and
right arrow keys.

14. Scroll Mode Switching

A check mark here indicates that this function is ON. When the scroll box in the
scroll bar of the data display area is dragged, the graph also scrolls according to

Advertising