Chapter 7: System Data Definition

7-16

Note:
Some parameters have a bit structure. Place the cursor over the current value location.
Double-click to show the pop-up window containing detailed information.

22

Maximum Value of Unlimited Length Counter
(posmax)

1~2147483647 (command unit)

23

Maximum Number of Absolute Encoder Rotations

1~2147483647 (1=1 rotation)

24

Positive Soft Limit

-2147483647 ~2147483647 (command unit)

25

Negative Soft Limit

-2147483647 ~2147483647 (command unit)

26

Zero Point Return Format

DEC signal + C-phase
DEC signal + ZERO signal
ZERO signal
C-phase

27

Backlash Compensation

0~32767 (command unit)

Table 5: Setting Data of Fixed Parameters (Continued)

No.

Fixed Parameter

Setting Data

F E D C B A 9 8 7 6 5 4 3 2 1 0

Command unit selection 0000: pulse 0010: deg

0001: mm 0011: inch

Electronic gearing (1: enable 0: disable)

Limited/Unlimited length selection (1: unlimited 0: limited)

Backlash compensation (fixed at 0: disabled)

Positive soft limit (1: enabled 0: disabled)

Negative soft limit (1: enabled 0: disabled)

Override (1: enabled 0: disabled)

Deceleration LS reverse (fixed at 0: disabled)

Reserved (fixed at 0)

Bits A and 6 cannot be set or changed.

Figure 1: Bit Structure of Parameter No. 17, Servo Module Function Select Flag