Parameter reference
16.2
Parameter list | C01227
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01227
C01228
C01229
Parameter | Name:
C01227 | MCK: Ref. positions
Data type: INTEGER_32
Index: 23348
d
= 5B34
h
Positions for determining the zero position of the reference measuring system
Setting range
(min. value | unit | max. value)
-214748.3647
unit
214748.3647
Subcodes
Lenze setting
Info
C01227/1
0.0000 unit
MCK: Ref. offset reference degree
• Relative traverse path by which the drive traverses
after detection of the reference initiator.
C01227/2
0.0000 unit
MCK: Ref. home position
• Position with which setpoint and actual position are
loaded after completion of homing.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01228 | MCK: Ref. sequence profile
Data type: UNSIGNED_8
Index: 23347
d
= 5B33
h
Number of the sequence profile the absolute position of which will be approached after homing.
Setting range
(min. value | unit | max. value)
Lenze setting
0
15 0
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01229 | MCK: Position limiting values
Data type: INTEGER_32
Index: 23346
d
= 5B32
h
Software limit position for limiting the valid traversing range
• The error response to leaving the valid traversing range can be parameterised in
and
Note:
For limiting the traversing range by means of software limit positions, the home position must be known and the
positive software limit position must be higher than the negative software limit position!
Setting range
(min. value | unit | max. value)
-214748.3647
units
214748.3647
Subcodes
Lenze setting
Info
C01229/1
0.0000 units
MCK: Positive SW limit position
(positive travel range limit)
C01229/2
0.0000 units
MCK: Negative SW limit position
(negative travel range limit)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000