Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1001

16

Parameter reference

16.2

Parameter list | C01227

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01227

C01228

C01229

Parameter | Name:

C01227 | MCK: Ref. positions

Data type: INTEGER_32

Index: 23348

d

= 5B34

h

Positions for determining the zero position of the reference measuring system

Homing

Setting range

(min. value | unit | max. value)

-214748.3647

unit

214748.3647

Subcodes

Lenze setting

Info

C01227/1

0.0000 unit

MCK: Ref. offset reference degree

• Relative traverse path by which the drive traverses

after detection of the reference initiator.

C01227/2

0.0000 unit

MCK: Ref. home position

• Position with which setpoint and actual position are

loaded after completion of homing.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000

Parameter | Name:

C01228 | MCK: Ref. sequence profile

Data type: UNSIGNED_8

Index: 23347

d

= 5B33

h

Number of the sequence profile the absolute position of which will be approached after homing.

Homing

Setting range

(min. value | unit | max. value)

Lenze setting

0

15 0

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01229 | MCK: Position limiting values

Data type: INTEGER_32

Index: 23346

d

= 5B32

h

Software limit position for limiting the valid traversing range

• The error response to leaving the valid traversing range can be parameterised in

C00595/3

and

C00595/4

.

Note:

For limiting the traversing range by means of software limit positions, the home position must be known and the

positive software limit position must be higher than the negative software limit position!

Limit position monitoring

Setting range

(min. value | unit | max. value)

-214748.3647

units

214748.3647

Subcodes

Lenze setting

Info

C01229/1

0.0000 units

MCK: Positive SW limit position

(positive travel range limit)

C01229/2

0.0000 units

MCK: Negative SW limit position

(negative travel range limit)

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000