4 touch probe positioning, Touch probe positioning, Touch probe positioning ( 521) – Lenze 8400 User Manual

Page 521: 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

521

8

Basic drive functions (MCK)

8.8

Positioning

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.8.2.4

Touch probe positioning

This function extension is available from version 06.00.00!

In case of a touch probe positioning, first the profile is executed according to the set profile

parameters. If a touch probe is detected during the process, it is automatically changed to the profile

defined in the "TP profile" profile parameter. This profile mode is also defined via the mode selection

like in the following profile start processes.
If no valid TP profile is set, the travel request is aborted ("PosStop").

Preconditions for touch probe positioning

• The mode of the current profile data set contains the setting "to TP".
• For absolute positioning, the home (reference) position must be known.
• In the corresponding profile data set, the following profile parameters must be set in addition:

• TP profile (

C1308/x

)

• TP signal source (

C1309/x

)

• The touch probe interface is configured such that the selected TP signal source is enabled.

• See chapter entitled "

Touch probe detection

".

( 331)

Note!

Go to

C02810/x

and select the edge, the digital input used for the connection of the

touch-probe sensor is to respond. In the Lenze setting of

C02810/x

, no touch probe is

detected!