5motor control (mctrl) – Lenze 8400 User Manual

Page 251

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

251

5

Motor control (MCTRL)

5.10

Parameterisable additional functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Explanation of the automatic DC-injection braking function by means of two examples

[5-27] Example 1: Signal characteristic for automatic DC-injection braking of a drive without speed feedback

[5-28] Example 2: Signal characteristic for automatic DC-injection braking of a drive with speed feedback

The motor rotates at a specified

speed. The current adjusts itself to

the load, see .

The DC braking current set in

C00036

is injected.

After the hold time (

C00106

) has

expired, a pulse inhibit is set.

 Speed setpoint

 Actual speed value of the motor

 Output current of the controller

 Pulse inhibit

 DC-injection braking is active

0

1

2

3

4



‚

C0107

C00036

C00019

ƒ

The motor rotates at the selected

speed. The resulting current depends

on the load, see .

The DC braking current set in

C00036

is injected.

The actual speed value of the

motor follows the speed setpoint.

The resulting current depends on the

load.

 Speed setpoint

 Actual speed value of the motor

 Output current of the controller

 Pulse inhibit

 DC-injection braking is active

0

1

2

3

4



‚

C00036

C00019

ƒ