5motor control (mctrl) – Lenze 8400 User Manual

Page 131

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

131

5

Motor control (MCTRL)

5.1

Motor selection/Motor data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Other motor data
Click the Other motor data... button and go to the Other motor data dialog box including the motor

equivalent circuit (in the following for an asynchronous motor):

Parameter

Info

ASM

PSM

C00084

Motor stator resistance

C00085

Motor stator leakage inductance

C00082

Motor rotor resistance

C00095

Motor magnetising current

C00092

Motor magnetising inductance

C00015

VFC: V/f base frequency

C00021

Slip compensation

C00070/1

SLVC: Vp speed controller

C00071/1

SLVC: Ti speed controller

C00075

Vp current controller

C00076

Ti current controller

C00273

Moment of inertia

C00016

VFC: Vmin boost

C00070/2

SC: Vp speed controller

C00071/2

SC: Ti speed controller

C00070/3

SLPSM: Vp speed controller

C00071/4

SLPSM: Ti speed controller

C00072

SC: Tdn speed controller

C00011

Appl.: Reference speed

C00022

Imax in motor mode

C00966

VFC: Time const. slip comp.

C00982

VFC-ECO: Voltage reduction ramp

C00073/1

VFC: Vp Imax controller

C00077

SC: Vp field controller

C00078

SC: Tn field controller

Advertising