C01093 - ls_parreadwrite 1-6: arithmetic mode, C01094 - ls_parreadwrite 1-6: numerator, 16 parameter reference – Lenze 8400 User Manual

Page 985

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

985

16

Parameter reference

16.2

Parameter list | C01093

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01093

C01094

Parameter | Name:

C01093 - LS_ParReadWrite 1-6: Arithmetic mode

Data type: UNSIGNED_8

Index: 23482

d

= 5BBA

h

From version 06.00.00

The integrated

arithmetic function

allows for easy arithmetic conversion of the process value to be written or which

was read into the format of the target parameter via parameterisable factors and without the need for an

additional arithmetic FB.
Selection list

0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647

Subcodes

Lenze setting

Info

C01093/1

0: no arithmetic

LS_ParReadWrite_1

: Arithmetic mode

C01093/2

0: no arithmetic

LS_ParReadWrite_2

: Arithmetic mode

C01093/3

0: no arithmetic

LS_ParReadWrite_3

: Arithmetic mode

C01093/4

0: no arithmetic

LS_ParReadWrite_4

: Arithmetic mode

C01093/5

0: no arithmetic

LS_ParReadWrite_5

: Arithmetic mode

C01093/6

0: no arithmetic

LS_ParReadWrite_6

: Arithmetic mode

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01094 - LS_ParReadWrite 1-6: Numerator

Data type: INTEGER_16

Index: 23481

d

= 5BB9

h

From version 06.00.00

Arithmetic function

: Factor (numerator) for internal conversion in arithmetic modes 1 ... 3.

Setting range

(min. value | unit | max. value)

-32767

32767

Subcodes

Lenze setting

Info

C01094/1

1

LS_ParReadWrite_1

: Numerator

C01094/2

1

LS_ParReadWrite_2

: Numerator

C01094/3

1

LS_ParReadWrite_3

: Numerator

C01094/4

1

LS_ParReadWrite_4

: Numerator

C01094/5

1

LS_ParReadWrite_5

: Numerator

C01094/6

1

LS_ParReadWrite_6

: Numerator

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1