6 reset error, 7 delete logbook, Reset error – Lenze 8400 User Manual

Page 106: Delete logbook, 4device control (dctrl)

Advertising
background image

4

Device control (DCTRL)

4.1

Device commands (C00002/x)

106

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.1.6

Reset error

The

C00002/19

= "1: On / start" device command acknowledges an existing error message if the

error cause has been eliminated and thus the error is no longer pending.

• After the reset (acknowledgement) of the current error, further errors may be pending which

must also be reset.

• The status determining error is displayed in

C00168

.

• The current error is displayed in

C00170

.

Tip!
An error message can also be acknowledged by activating the Reset error button in the

Diagnostics tab.
Detailed information on error messages can be found in the "

Diagnostics & error

management

" chapter.

( 553)

4.1.7

Delete logbook

The

C00002/21

= "1: On / start" device command deletes all logbook entries.

Tip!
To display the logbook in the »Engineer«, click the Logbook button on the Diagnostics tab.
In the Logbook dialog box, it is also possible to delete all logbook entries by clicking the

Delete button.
Detailed information on the logbook can be found in the "

Diagnostics & error

management

" chapter.

( 553)

Advertising