18 function library – Lenze 8400 User Manual

Page 1248

Advertising
background image

18

Function library

18.1

Function blocks | L_Curve_3

1248

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

Parameter

Identifier

Data type

Value/meaning

nOut_a

INT

Output value (y)

• ±16384 ≡ ±100 %

• Internal limitation to ±32767 (±199.99 %)

When using the FB for tensile force characteristic

(from V12.00.00)

:

Current tensile force setpoint in [%]

• 16384 ≡ 100 %

bLimit

BOOL

"Limitation active" status signal

TRUE The output value is limited to ±199.99 %.

nCurveValue_a

INT

From version 12.00.00

Current characteristic value of the tensile force characteristic in [%]

Parameter

Possible settings

Info

C00959/3

-199.99

%

199.99 Output value

• Read only

C01030/1

Function selection

0 Out = 0

FB deactivated (Lenze setting)

1 Out = In
2 Out = f(In)

In preparation!

3 Out = f(table)

See description of L_Curve_1:

Function 3: nOut_a = f(table)

4 Out = f(characteristic)

Use of the L_Curve_3 for tensile

force characteristic

C01031/1

-199.99

%

199.99 Upper limit for input value

• Lenze setting: 199.99 %

C01031/2

-199.99

%

199.99 Lower limit for input value

• Lenze setting: -199.99 %

C01033/1...32

-32767

32767 X values for characteristic function

• Subcodes 1 ... 32 correspond to

interpolation point values

X1 ... X32.

• ±16384 ≡ ±100 %

• Lenze setting: 0

See description of L_Curve_1:

Function 3: nOut_a = f(table)

C01034/1...32

-32767

32767 Y values for characteristic function

• Subcodes 1 ... 32 correspond to

interpolation point values

Y1 ... Y32.

• ±16384 ≡ ±100 %

• Lenze setting: 0

See description of L_Curve_1:

Function 3: nOut_a = f(table)