C00166 | error information text, C00168 | status determining error, C00166/3 – Lenze 8400 User Manual

Page 783: C00168, C00166/1, C00166/2, C00166/4, C00166/5, C00166/6, Lenze error number

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

783

16

Parameter reference

16.2

Parameter list | C00166

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00166

C00167

C00168

Parameter | Name:

C00166 | Error information text

Data type: VISIBLE_STRING

Index: 24409

d

= 5F59

h

Display of details on the status determining error and on the currently pending error
Subcodes

Info

C00166/1

Resp. to status det. error

• Response to the status determining error

C00166/2

Subj. - status det. error

• Subject area of the status determining error

C00166/3

Mess. - status det. error

• Textual message of the status determining error

C00166/4

Resp. to curr. error

• Response of the currently pending error

C00166/5

Subj. - curr. error

• Subject area of the currently pending error

C00166/6

Mess. - curr. error

• Textual message of the currently pending error

Read access  Write access  CINH  PLC-STOP  No transfer  COM  MOT

Character length: 31

Parameter | Name:

C00167 | Logbook data

Data type: OCTET_STRING

Index: 24408

d

= 5F58

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00168 | Status determining error

Data type: UNSIGNED_32

Index: 24407

d

= 5F57

h

Display of the internal error number for the status determining error
Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising