16

Parameter reference

16.2

Parameter list | C01218

998

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01218

C01219

Parameter | Name:

C01218 | PosFollower: Setting

Data type: UNSIGNED_8

Index: 23357

d

= 5B3D

h

Settings for "Position follower" mode

Position follower

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x0C (decimal: 12)

Value is bit-coded: (= bit set)

Info

Bit 0  Speed FF control.: nSpeedSetValue_a "1" ≡ speed feedforward control value comes from main

setpoint nSpeedSetValue_a

Bit 1  Speed FF control: nSpeedAddValue_v "1" ≡ speed feedforward control value comes from

additive speed value nSpeedAddValue_v

Bit 2  HW limit switch on

"1" ≡ Travel range monitoring via hardware limit switch

is active. The error response can be parameterised in

C00595/1

and

C00595/2

.

Bit 3  SW limit switch on

"1" ≡ Travel range monitoring via parameterised

software limit positions is active. The error response can

be parameterised in

C00595/3

and

C00595/4

.

Bit 4  Reserved
Bit 5  Reserved
Bit 6  Reserved
Bit 7  Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C01219 | MCK: Speed follower setting

Data type: UNSIGNED_8

Index: 23356

d

= 5B3C

h

Settings for "Speed follower" mode

Speed follower

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x0C (decimal: 12)

Value is bit-coded: (= bit set)

Info

Bit 0  Reserved
Bit 1  Reserved
Bit 2  HW limit switch on

"1" ≡ Travel range monitoring via hardware limit switch

is active. The error response can be parameterised in

C00595/1

and

C00595/2

.

Bit 3  SW limit switch on

"1" ≡ Travel range monitoring via parameterised

software limit positions is active. The error response can

be parameterised in

C00595/3

and

C00595/4

.

Bit 4  Reserved
Bit 5  Reserved
Bit 6  Reserved
Bit 7  Position controller off

"1" ≡ Position controller is deactivated. Thus, the

compensation of the following error is switched off.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT