18 function library – Lenze 8400 User Manual
Page 1222
18
Function library
18.1
Function blocks | L_ConvW_1
1222
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Conversion formulae
[18-19] Conversion formula for selection 1: [%] [incr/ms]
[18-20] Conversion formula for selection 2: [incr/ms] [%]
[18-21] Conversion formula for selection 3: Parameterisable factors
Note!
In case of this FB, division is remainder considered.
wOut [incr/ms]
wIn [%] C00011 [rpm] 65536 [incr/rev.]
⋅
⋅
100 % 60 [s/min] 1000 [ms/s]
⋅
⋅
------------------------------------------------------------------------------------------------------------
=
wOut [%]
wIn [incr/ms] 100 % 60 [s/min] 1000 [ms/s]
⋅
⋅
⋅
C00011 [rpm] 65536 [incr/rev.]
⋅
---------------------------------------------------------------------------------------------------------------------------
=
wOut
wIn C00940
C00941
--------------------
⋅
=