Parameter reference

16.2

Parameter list | C00995

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00995

C00996

C00997

C00998

Parameter | Name:

C00995 | SLPSM: Controlled current setpoint

Data type: UNSIGNED_16

Index: 23580

d

= 5C1C

h

From version 12.00.00

Sensorless control for synchronous motor

Setting range

(min. value | unit | max. value)

5.00

%

400.00

Subcodes

Lenze setting

Info

C00995/1

100.00 %

SLPSM: Controlled accelerating current

C00995/2

20.00 %

SLPSM: Controlled standstill current

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00996 | SLPSM: Switching speed

Data type: INTEGER_16

Index: 23579

d

= 5C1B

h

From version 12.00.00

Sensorless control for synchronous motor

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C00996/1

13.00 %

SLPSM: Switching speed, closed-loop control

C00996/2

8.00 %

SLPSM: Switching speed, open-loop control

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00997 | SLPSM: Filter cutoff frequency

Data type: INTEGER_16

Index: 23578

d

= 5C1A

h

From version 12.00.00

Sensorless control for synchronous motor

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 5.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00998 | SLPSM: Filter time rotor position

Data type: INTEGER_16

Index: 23577

d

= 5C19

h

From version 12.00.00

Sensorless control for synchronous motor

Setting range

(min. value | unit | max. value)

0.5

ms

20.0

Subcodes

Lenze setting

Info

C00998/1

3.0 ms

SLPSM: Filter time rotor position

C00998/2

5.0 ms

SLPSM: Filter time actual speed value

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10