C00643 | resp. to pli monitoring, C00650 | l_arithmetik 3-5: function, 16 parameter reference – Lenze 8400 User Manual

Page 870

Advertising
background image

16

Parameter reference

16.2

Parameter list | C00643

870

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00643

C00650

Parameter | Name:

C00643 | Resp. to PLI monitoring

Data type: UNSIGNED_8

Index: 23932

d

= 5D7C

h

From version 12.00.00

Pole position identification without motion

Selection list

0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00643/1

1: Fault

Response to PLI monitoring

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00650 | L_Arithmetik 3-5: Function

Data type: UNSIGNED_8

Index: 23925

d

= 5D75

h

Selection of the internal arithmetics
Selection list

0 nOut_a = nIn1_a
1 nOut_a = nIn1_a + nIn2_a
2 nOut_a = nIn1_a - nIn2_a
3 nOut_a = (nIn1_a * nIn2_a) / 100%
4 nOut_a = (nIn1_a * 1%) / |nIn2_a|
5 nOut_a = (nIn1_a * 100%) / (100% -

nIn2_a)

Subcodes

Lenze setting

Info

C00650/1

0: nOut_a = nIn1_a

L_Arithmetik_3

: Function

C00650/2

0: nOut_a = nIn1_a

L_Arithmetik_4

: Function

C00650/3

0: nOut_a = nIn1_a

L_Arithmetik_5

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising