2 operating mode change with profile number, Operating mode change with profile number, 8basic drive functions (mck) – Lenze 8400 User Manual

Page 463

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

463

8

Basic drive functions (MCK)

8.3

MCKInterface

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

SetProfilPosition at position change
If bit 3 is set in

C01297

, the setpoint positions at the MCKInterface are automatically accepted into

the profile with the applied profile number if a change of data is detected at the corresponding

input for the setpoint position.

• If the "0: dnPosOut_p=dnPosIn_p" mode has been set in

C01296/1

for converting the position,

automatic acceptance is executed if the incremental position selection at the dnPosIn_p input

was changed.

• If another mode (>0) has been set in

C01296/1

, automatic acceptance is executed if the

incremental position selection at the wPosUnitsLW and wPosUnitsHW inputs was changed.

From version 12.00.00

a hysteresis can be set in

C01245/3

for the position change.

PosExecute at position change

(from version 12.00.00)

If bit 4 is set in

C01297

, an automatic "PosExecute" takes place if the incremental position selection

changes and this change is higher than set in the hysteresis for position change (

C01245/3

).

If the selection is made in units, so that in a first step it has to be converted into increments, and if

this automatic function is then activated, the "PosExecute" will only be created automatically when

the internal conversion is completed (bPosSetDataValid).

Tip!
This option serves to start travel requests very easily by simply defining the new target

position.

8.3.1.2

Operating mode change with profile number

One of the operating modes of the LS_MotionControlKernel system block can be assigned to the

positioning profiles via the four subcodes of

C01298

:

• When a changeover to the corresponding profile is carried out, the set operating module is

requested at the same time.

• In the case of the setting "0: No change", the operating mode is not changed when the profile

changeover occurs. Instead, the operating mode requested "from outside" via the

MCK control

word

is applicable.

Parameter

Info

Lenze setting

C01298/1

Operating mode if profile 0 is selected

Speed follower

C01298/2

Operating mode if profile 1 is selected

Homing

C01298/3

Operating mode if profile 2 is selected

Manual jog

C01298/4

Operating mode if profile 3 ... 15 is selected

Positioning