18
Function library
18.1
Function blocks | L_SignalSwitch32_3
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.159
L_SignalSwitch32_3
This FB switches between two input signals of the "DINT" data type. The switch-over is controlled by
means of a boolean input signal.
Inputs
Outputs
Identifier
Data type
Information/possible settings
dnIn1
DINT
Input signal 1
dnIn2
DINT
Input signal 2
bSet
BOOL
Selection of the input signal for the output at dnOut
FALSE dnIn1
TRUE dnIn2
Identifier
Data type
Value/meaning
dnOut
DINT
Output signal