3 limit position monitoring, 1 software limit positions, Limit position monitoring – Lenze 8400 User Manual

Page 474: Software limit positions, 8basic drive functions (mck), Stop

Advertising
background image

8

Basic drive functions (MCK)

8.4

Basic settings

474

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.4.3

Limit position monitoring

8.4.3.1

Software limit positions

The parameterisable limit positions are used by the software to limit the traversing range.

• The positive software limit position is set in

C01229/1

and the negative software limit position

is set in

C01229/2

.

[8-15] Definition of the software limit position trigger limits

Stop!

The software limit positions are only evaluated and monitoring if the drive knows the

home position and the software limit positions for the respective operating mode have

been activated.

• For the "manual jogging" operating mode, travel range monitoring is switched off by

means of parameterisable software limit positions in the Lenze setting of

C01230

.

• In the "

Homing

" and "

Positioning

" operating modes, the travel range monitoring is

generally switched-on.

Parameter

Info

Lenze setting

C01218

- Bit 3

SW limit positions for position follower on/off

On

C01219

- Bit 3

SW limit positions for speed follower on/off

On

C01230

- Bit 3

SW limit position for manual jogging on/off

Off

 Error range (actual position)

 Set position

 Actual position

C01229/1

: Positive software limit position

C01229/2

: Negative software limit position

0

Œ

C01229/1



C01229/2

wMotionState1 - Bit 14: Pos. SW-Limit Detected

wMotionState1 - Bit 15: Neg. SW-Limit Detected

SetPos

1

2 ActPos

t

t

t

0

0

Position

(absolute)

+32767 Incr.

-32767 Incr.

+32767 Incr.

-32767 Incr.

Advertising