C02231 | ls_writeparamlist: rated motor power, C02232 | ls_writeparamlist: motor rotor resistance, C02231/1 – Lenze 8400 User Manual

Page 1030: C02231/2, C02231/3, C02231/4, C02232/1, C02232/2, C02232/3, C02232/4

Advertising
background image

16

Parameter reference

16.2

Parameter list | C02231

1030

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02231

C02232

C02233

Parameter | Name:

C02231 | LS_WriteParamList: Rated motor power

Data type: UNSIGNED_16

Index: 22344

d

= 5748

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

kW

500.00

Subcodes

Lenze setting

Info

C02231/1

11.00 kW

LS_WriteParamList

: c81_val1

C02231/2

11.00 kW

LS_WriteParamList

: c81_val2

C02231/3

11.00 kW

LS_WriteParamList

: c81_val3

C02231/4

11.00 kW

LS_WriteParamList

: c81_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02232 | LS_WriteParamList: Motor rotor resistance

Data type: UNSIGNED_32

Index: 22343

d

= 5747

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

mOhm

200000

Subcodes

Lenze setting

Info

C02232/1

276 mOhm

LS_WriteParamList

: c82_val1

C02232/2

276 mOhm

LS_WriteParamList

: c82_val2

C02232/3

276 mOhm

LS_WriteParamList

: c82_val3

C02232/4

276 mOhm

LS_WriteParamList

: c82_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02233 | LS_WriteParamList: Motor stator resistance

Data type: UNSIGNED_32

Index: 22342

d

= 5746

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

mOhm

200000

Subcodes

Lenze setting

Info

C02233/1

330 mOhm

LS_WriteParamList

: c84_val1

C02233/2

330 mOhm

LS_WriteParamList

: c84_val2

C02233/3

330 mOhm

LS_WriteParamList

: c84_val3

C02233/4

330 mOhm

LS_WriteParamList

: c84_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising