105 l_mux_1, 105 l_mux_1 9, L_mux_1 – Lenze 8400 User Manual

Page 1319: 18 function library

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1319

18

Function library

18.1

Function blocks | L_Mux_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

18.1.105

L_Mux_1

This FB provides one of the eight input signals dnIn1_p ... dnIn8_p at the output dnOut_p. The

selection is made by means of the signal at the input wInSelect.

Inputs

Outputs

Identifier

Data type

Information/possible settings

wInSelect

WORD

Input signal

1 ... 8

• The values "1" ... "8" select the input signal to be applied to the

output.

• Values from"1" ... "8" set the dnOut_p output to "0".

dnIn1_p

DINT

...

dnIn8_p

DINT

Input signal

Identifier

Data type

Value/meaning

dnOut_p

DINT

Output signal

/B0X[B

Z,Q6HOHFW

GQ2XWBS

GQ,QBS





GQ,QBS



GQ,QBS



GQ,QBS



GQ,QBS



GQ,QBS



GQ,QBS



GQ,QBS





!