C00073 | imax/m controller gain, C00074 | reset time imax/m controller, C00075 | vp current controller – Lenze 8400 User Manual

Page 757: C00076 | ti current controller, C00075, C00076, C00073/1, C00074/1, C00074, C00073

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

757

16

Parameter reference

16.2

Parameter list | C00073

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00073

C00074

C00075

C00076

Parameter | Name:

C00073 | Imax/M controller gain

Data type: UNSIGNED_16

Index: 24502

d

= 5FB6

h

Amplification factor Vp of certain controllers for different motor control modes
Setting range

(min. value | unit | max. value)

0.00

100.00

Subcodes

Lenze setting

Info

C00073/1

0.25

VFC

: Vp Imax controller

• After the motor to be used has been selected from the

motor catalogue, the suitable value can be entered

automatically.

C00073/2

1.25

SLVC

: Vp torque controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00074 | Reset time Imax/M controller

Data type: UNSIGNED_16

Index: 24501

d

= 5FB5

h

Reset time Ti of certain controllers for different motor control modes
Setting range

(min. value | unit | max. value)

0

ms

9990

Subcodes

Lenze setting

Info

C00074/1

65 ms

VFC

: Ti Imax controller

C00074/2

30 ms

SLVC

: Ti torque controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00075 | Vp current controller

Data type: UNSIGNED_16

Index: 24500

d

= 5FB4

h

Gain factor Vp of the current controller for servo control (

SC

) and certain inverter functions (parameter

identification, flying restart circuit)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

500.00 7.00 V/A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00076 | Ti current controller

Data type: UNSIGNED_16

Index: 24499

d

= 5FB3

h

Reset time Ti of the current controller for servo control (

SC

) and certain inverter functions (parameter identification,

flying restart circuit)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

500.00 10.61 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising