143 l_pt1_1, 143 l_pt1_1 9, L_pt1_1 – Lenze 8400 User Manual
Page 1389: 18 function library
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1389
18
Function library
18.1
Function blocks | L_PT1_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.143
L_PT1_1
This FB filters and delays analog signals.
• The filter time constant T can be set under
• The gain is defined with V
p
= 1.
Inputs
Outputs
Parameter
Function
[18-60] Filter time constant T of the first-order delay element
Identifier
Data type
Information/possible settings
nIn_a
INT
Input signal
Identifier
Data type
Value/meaning
nOut
INT
Output signal
Parameter
Possible settings
Info
0
ms
5000 Filter time constant
• The filter is not active with a
setting of "0 ms". The input signal
is passed through one-to-one to
the output.
• Lenze setting: 2000 ms
/B37B
)LOWHUWLPH
&
Q,QBD
Q2XWBD
T
V = 1
p
t