8basic drive functions (mck) – Lenze 8400 User Manual

Page 519

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

519

8

Basic drive functions (MCK)

8.8

Positioning

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Final speed (

C01305/1...15

)

This specifies the speed at which the drive is to start the next profile after reaching the target position.

With a final speed not equal to "0", "velocity changeover" or "overchange" is possible, i.e. when the

target position is reached, a second positioning process is started immediately without the drive coming

to a standstill at the first target position.

Target position

Final speed (in this case, not equal to "0")

Sequence profile (

C01307/1...15

)

for profile linkage/following block control

A special feature is automatic advancing to subsequent profiles with and without velocity changeover.

For this purpose, the profile number of the desired subsequent profile (1 to 15) is simply set in the

parameter "Sequence profile" (

C01307/1...15

) of a profile.

After execution of the profile (target position reached), the set following (subsequent) profile is started

automatically. In this way, profile chains can be stipulated without additional control processes.

• If the profile parameter "Final speed" (

C01305/1...15

) is set to <> "0", there is a velocity changeover

leading into the following (subsequent) profile at the set final speed.

• If "0" is set for the following (i.e. subsequent) profile, profile linkage does not take place.

• This function can be performed in all positioning modes.

From version 06.00.00 onwards:

TP profile (

C01308/1...15

)

Profile number of the profile (1 … 15) that is to be executed after a touch probe has been detected.

• If "0" is set, there will be no profile stepping through touch probe.

• Only relevant for positioning modes with touch-probe.

Touch probe positioning ( 521)

From version 06.00.00 onwards:

TP signal source (

C01309/1...15

)

Selection of the signal source for touch probe detection.

• Only relevant for positioning modes with touch-probe.

Touch probe positioning ( 521)

Icon

Profile parameter

F

Œ



v

pos

v

end

v [m/s]