C00760

Parameter | Name:

C00760 | LA_SwitchPos: Analog connection list

Data type: UNSIGNED_16

Index: 23815

d

= 5D07

h

Connection parameters for "Switch-off positioning" application: 16-bi inputs

• Selection of the 16 bit output signals to be connected to the 16 bit input signals

• The selection list contains all 16 bit output signals which can be assigned to the 16 bit inputs displayed by the

subcodes.

Selection list
See

selection list - analog signals

Subcodes

Lenze setting

Info

C00760/1

0: Not connected

LA_SwitchPos

: wCANDriveControl

Input for control word from CAN to device control

C00760/2

0: Not connected

LA_SwitchPos

: wMCIDriveControl

Input for control word from communication interface to

device control

C00760/3

0: Not connected

LA_SwitchPos

: nVoltageAdd_a

Input for additive voltage impression

C00760/4

0: Not connected

LA_SwitchPos

: nBoost_a

Input for additional setpoint for motor voltage at speed

= 0

C00760/5

0: Not connected

LA_SwitchPos

: nPWMAngleOffset

Input for additional offset for the electrical angle of

rotation

C00760/6

0: Not connected

LA_SwitchPos

: nTorqueMotLim_a

Input for maximum torque in motor mode

C00760/7

0: Not connected

LA_SwitchPos

: nTorqueGenLim_a

Input for maximum torque in generator mode

C00760/8

0: Not connected

LA_SwitchPos

: nMainSetValue_a

Input for main speed setpoint

C00760/9

0: Not connected

LA_SwitchPos

: nAuxSetValue_a

Input for additional speed setpoint

C00760/10

0: Not connected

LA_SwitchPos

: nGPAnalogSwitchIn1_a

Input for analog switch - analog signal 1

C00760/11

0: Not connected

LA_SwitchPos

: nGPAnalogSwitchIn2_a

Input for analog switch - analog signal 2

C00760/12

0: Not connected

LA_SwitchPos

: nGPArithmetikIn1_a

Input for arithmetic function - analog signal 1

C00760/13

0: Not connected

LA_SwitchPos

: nGPArithmetikIn2_a

Input for arithmetic function - analog signal 2

C00760/14

0: Not connected

LA_SwitchPos

: nGPMulDivIn_a

Input for analog signal for multiplication/division

C00760/15

0: Not connected

LA_SwitchPos

: nGPCompareIn1_a

Input for comparison operation - analog signal 1

C00760/16

0: Not connected

LA_SwitchPos

: nGPCompareIn2_a

Input for comparison operation - analog signal 2

C00760/17

0: Not connected

LA_SwitchPos

: wSMCtrl

Interface to the optional safety system

C00760/18

0: Not connected

Reserved

C00760/19

0: Not connected

Reserved

C00760/20

0: Not connected

Reserved

C00760/21

0: Not connected

Reserved