2 mck status word, Mck status word, Ation of the – Lenze 8400 User Manual

Page 447: 8basic drive functions (mck)

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

447

8

Basic drive functions (MCK)

8.2

Internal interfaces | System block "LS_MotionControlKernel"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.2.2

MCK status word

MCK status word 1 (wMotionState1)

Bit

Designation

Description

0

...

3

ActOpModeBit00

...

ActOpModeBit03

Active operating mode

Bit 3

Bit 2

Bit 1

Bit 0

Speed follower

0

0

0

0

Homing

0

0

0

1

Manual jog

0

0

1

0

Positioning

0

0

1

1

Stop

or

Safe stop 1 (SS1)

0

1

0

0

Position follower

0

1

0

1

StandBy (internal operating mode in the event of

quick stop, pulse inhibit, and DC-injection braking)

1

1

1

1

4 Busy

"1" ≡ Internal profile generation is active. A speed profile is being generated.

5 Done

"1" ≡ Generation of a speed profile with the selected position has been completed.

6 AcceleratingActive

"1" ≡ Profile generation phase is in the acceleration process.

7 ConstSpeedDuty

"1" ≡ Profile generation phase at constant speed active.

8 DeceleratingActive

"1" ≡ Profile generation phase is in the deceleration process.

9 S_ShapingActive

From version 12.00.00:

"1" ≡ Rounding during acceleration/deceleration active.

Status bit "S_ShapingActive"

10 Pos. HW-Limit

Detected

"1" ≡ Positive limit switch has triggered.

• Reset only possible via"Manual jog" mode!

Hardware limit switch

11 Neg. HW-Limit

Detected

"1" ≡ Negative limit switch has triggered.

• Reset only possible via"Manual jog" mode!

Hardware limit switch

12 HomPosDone

"1" ≡ Homing has been completed.

13 HomPosAvailable

"1" ≡ The home position has been detected and is known in the drive.

Status bit "HomPosAvailable"

14 Pos. SW limit

detected

"1" ≡ Positive software limit position overtravelled.

Software limit positions

15 Neg. SW limit

detected

"1" ≡ Negative software limit position overtravelled.

Software limit positions

Note!

The internal "

StandBy

" operating mode is assumed if pulse inhibit, quick stop and/or DC-

injection braking are activated.

• No setpoint generation via the Motion Control Kernel in this operating mode.
• If the holding brake control sets a controller inhibit when the holding brake is closed,

the internal "StandBy" operating mode is not assumed.