1 parameterising analog input, Parameterising analog input, Parameterising analog input ( 327) – Lenze 8400 User Manual

Page 327: 6i/o terminals

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

327

6

I/O terminals

6.2

Analog terminals

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2.1

Parameterising analog input

By clicking on the

button on the Terminal assignment tab, you reach the parameterising

dialog for the analog input:

Short overview of the parameters for the analog input:

Using current input A1I
In the Lenze setting, voltage signals in the 0 ... +10 V range are evaluated via the analog input A1U.

If current signals are to be detected via the input A1I instead, the selection "1: 0...20 mA" or "2:

4...20mA" must be set in

C00034

.

Tip!
By selecting "2: 4...20mA", you can implement a 4 ...20 mA current loop, e.g. for stipulation

of the speed setpoint.

Open-circuit monitoring
In the case of configuration as a 4 ... 20 mA current loop, the fault response set in

C00598

takes place

in the event of a wire breakage (Lenze setting: "TroubleQuickStop").

Parameter

Info

Lenze setting

Value Unit

Analog input 1

C00034/1

AIN1: Config.

0: 0 V .... + 10 V

C00026/1

AIN1: Offset

0.00 %

C00027/1

AIN1: Gain

1.0000

C00028/1

AIN1: Input voltage

- V

C00029/1

AIN1: Input current

- mA

C00033/1

AIN1: Output value (to application)

- %

C00440/1

PT1 rounding AnalogIn1

10 ms

C00598/1

Resp. to open circuit AIN1

3: TroubleQuickStop

Highlighted in grey = display parameter