Basic drive functions (MCK)

8.10

Position follower

530

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Position controller off
If this function is activated via bit 7 in

C01218

, the position controller is deactivated in this operating

mode. Hence, following error control is switched-off.

8.10.2

Requesting the operating mode

Requesting the "position follower" operating mode by means of the

MCK control word

:

If the MCKInterface is connected upstream to the Motion Control Kernel and if the operating mode

is requested at the

L_MckCtrlInterface

FB, the wOperationMode and bOperationMode_1...8 process

inputs are available.

8.10.3

Setpoint selection

The absolute position setpoint is stipulated via the dnPosSetValue_p process input.

Compensating following errors
If the bDeltaPosOn process input is set to TRUE, a position difference (following error) is

compensated for which is not internally generated from setpoint/actual positions but must be

defined via the dnDeltaPos_p process input instead.

MCK control word

Bit 31

...

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

OpMode_Bit3

OpMode_Bit2

OpMode_Bit1

OpMode_Bit0

X

...

X

0

1

0

1

X = Status not significant

Note!

The bPosCtrlOn process input must be set to TRUE so that position/angle control is active

within motor control.