C01243 | mck: current operating mode, C01244 | mck: target detection - times, C01243 – Lenze 8400 User Manual

Page 1009: Is displayed in, C01215/1, C01244/3, C01244/1, Time set in, C01244/2, C01244/x

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1009

16

Parameter reference

16.2

Parameter list | C01243

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01243

C01244

Parameter | Name:

C01243 | MCK: Current operating mode

Data type: UNSIGNED_8

Index: 23332

d

= 5B24

h

Display of the active operating mode of the Motion Control Kernel

Basic drive functions

Selection list

(read only)

Info

0 Speed follower

Drive traverses according to a preselected speed setpoint

1 Homing

Drive finds its reference measuring system by setting the

home position or homing

2 ManualJog

Drive can be traversed manually via initiators, e.g. for

cleaning purposes or tool changes.

3 Positioning

Drive traverses according to defined travel profiles and

motion processes

4 Stop

Drive is decelerated to standstill along a parameterised

deceleration ramp

5 Position follower

Drive traverses according to a preselected position

setpoint

15 StandBy

Internal operating mode for quick stop and pulse inhibit

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01244 | MCK: Target detection - times

Data type: UNSIGNED_16

Index: 23331

d

= 5B23

h

Timing for various MCK functions
Setting range

(min. value | unit | max. value)

0

ms

60000

Subcodes

Lenze setting

Info

C01244/1

100 ms

MCK: Dwell time - target position

• Time expiring after reaching the setpoint position for

positioning processes and enabling the actual

position detection in the target position window.

Target position monitoring

C01244/2

0 ms

MCK: Waiting time following error 1

From version 12.00.00

Following error monitoring system

C01244/3

0 ms

MCK: Waiting time following error 2

From version 12.00.00

Following error monitoring system

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1