C00877 | mci output words, C00890 | mci_inout: inversion, C00890/1 – Lenze 8400 User Manual

Page 949: C00890/3, C00877/1, C00877/2, C00890/2, C00890/4, 16 parameter reference

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

949

16

Parameter reference

16.2

Parameter list | C00877

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00877

C00890

Parameter | Name:

C00877 | MCI output words

Data type: UNSIGNED_16

Index: 23698

d

= 5C92

h

Display of the 16 bit output values of the communication module
Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Active

... ...

Bit 15 Active

Subcodes

Info

C00877/1

LP_MciOut

: wState

C00877/2

LP_MciOut

: wOut2

C00877/3

LP_MciOut

: wOut3

C00877/4

LP_MciOut

: wOut4

C00877/5

LP_MciOut

: wOut5

C00877/6

LP_MciOut

: wOut6

C00877/7

LP_MciOut

: wOut7

C00877/8

LP_MciOut

: wOut8

C00877/9

LP_MciOut

: wOut9

C00877/10

LP_MciOut

: wOut10

C00877/11

LP_MciOut

: wOut11

C00877/12

LP_MciOut

: wOut12

C00877/13

LP_MciOut

: wOut13

C00877/14

LP_MciOut

: wOut14

C00877/15

LP_MciOut

: wOut15

C00877/16

LP_MciOut

: wOut16

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C00890 | MCI_InOut: Inversion

Data type: UNSIGNED_16

Index: 23685

d

= 5C85

h

This parameter serves to invert the control/status bits of the MCI port blocks.
Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Active

Bit set = inversion active

... ...

Bit 15 Active

Subcodes

Lenze setting

Info

C00890/1

0x0000

LP_MciIn

: Invert.Ctrl_B0..15

C00890/2

0x0000

LP_MciOut

: Invert.State_B0..15

C00890/3

0x0000

LP_MciIn

: Invert. In2_B0..15

C00890/4

0x0000

LP_MciOut

: Invert.Out2_B0..15

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Advertising