6

I/O terminals

6.1

Digital terminals

320

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Counting input DI5

Using DI1(5) as counting input

bCountIn1_Compare

BOOL

Status signal "Comparison value reached"

FALSE Current count value < comparison value (

C02840/4

)

TRUE Current count value ≥ comparison value (

C02840/4

)

wCountIn6_HW

wCountIn6_LW

C02841/2

| WORD

Current count value

• Output as High and Low word (without sign)

• Possible counting range: 0 ... 2

31

- 1

Frequency input DI5/DI6

Using DI1(5) and DI2(6) as frequency inputs

nFreqIn56_a

C00446/2

| INT

Output frequency as scaled analog signal in [%]

nFreqIn56_v

C00445/2

| INT

Output frequency as speed signal in [inc/ms]