Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Counting input DI5
Using DI1(5) as counting input
bCountIn1_Compare
BOOL
Status signal "Comparison value reached"
FALSE Current count value < comparison value (
)
TRUE Current count value ≥ comparison value (
)
wCountIn6_HW
wCountIn6_LW
| WORD
Current count value
• Output as High and Low word (without sign)
• Possible counting range: 0 ... 2
31
- 1
Frequency input DI5/DI6
Using DI1(5) and DI2(6) as frequency inputs
nFreqIn56_a
| INT
Output frequency as scaled analog signal in [%]
nFreqIn56_v
| INT
Output frequency as speed signal in [inc/ms]
Identifier
DIS code | data type
Value/meaning