18.1

Function blocks | L_CalcDiameter_1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01050/1

0.001

Rev.

2.000 Diameter recalculation 0

• Number of revolutions after

which a diameter calculation is

executed.

• Setting is effective when bCalcRef

= FALSE.

• Initialisation: 1.000

C01050/2

0.001

Rev.

2.000 Diameter recalculation 1

• Number of revolutions after

which a diameter calculation is

executed.

• Setting is effective when bCalcRef

= TRUE.

• Initialisation: 0.100

C01051/1

0.010

s

3.000 Filter time constant for calculated

diameter values

• Initialisation: 1.000 s

C01052/1

0.00

%

100.00 Permissible diameter change in

opposite direction (web break

monitoring)

• Only relevant when bUnidirect =

TRUE.

• Referring to the maximum

diameter (wMaxDiameter).

• Initialisation: 10.00 %

C01057/1

0.000

mm

10000.000 Current diameter

• Read only

C01067/3

Invert. gearbox nMotorSpeedAct_v

0 not inverted
1 inverted
2 Automatically from MCK

Parameter

Possible settings

Info