Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

55

3

Commissioning

3.7

Commissioning of the "Actuating drive speed" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.7

Commissioning of the "Actuating drive speed" technology application

[3-1]

Block diagram for wiring the commissioning example for the "Actuating drive speed" application

Commissioning steps
Find a description of the commissioning steps of the "Actuating drive speed" technology application

below.
Please observe the sequence of the steps in the following chapters and follow them through

carefully. This will help you to commission your controller quickly and as safely as possible:

Prepare controller for commissioning

Creating an »Engineer« project & going online

( 57)

Parameterising the motor control

( 58)

Parameterise application

( 59)

Saving parameter settings safe against mains failure

( 61)

Enable controller and test application

( 61)

Note!

Take all the necessary safety precautions before you carry out the following

commissioning steps and switch the device on!

Safety instructions with regard to commissioning

( 49)

System constellation

X50/AR

Reference voltage (10 V) for analog signals

X50/A1U

Speed setpoint selection (slider of setpoint potentiometer R)

• Scaling: 10 V ≡ 100 % ≡ 1500 rpm

1

(for a 4-pole motor)

X50/GA

Ground potential (GND) for analog signals

X70

Diagnostic interface for connecting the USB diagnostic adapter

8400 protec

X61

X6

DIAG

AR A1U GA

X50

24O DI1 DI2 GIO

X41

24O DI3 DI4 GIO

X42

24O DI5 DI6 GIO

X43

U

V W

X70

M

3~

i

R

1k

... 10k

W

W