1063

16

Parameter reference

16.2

Parameter list | C02840

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02840

C02841

C02842

Parameter | Name:

C02840 | CountInx: Parameter

Data type: UNSIGNED_32

Index: 21735

d

= 54E7

h

Starting and comparison values for digital count inputs

Use DI1(5) as counting input

Setting range

(min. value | unit | max. value)

0

Incr.

2147483647

Subcodes

Lenze setting

Info

C02840/1

0 incr.

CountIn1: Starting value

C02840/2

65535 incr.

CountIn1: Comparison value

C02840/3

0 incr.

CountIn5: Starting value

C02840/4

65535 incr.

CountIn5: Comparison value

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02841 | CountInx: Counter content

Data type: UNSIGNED_32

Index: 21734

d

= 54E6

h

Display of the current counter content of the digital count inputs

Use DI1(5) as counting input

Display range

(min. value | unit | max. value)

0

Incr.

2147483647

Subcodes

Info

C02841/1

CountIn1: Counter content

C02841/2

CountIn5: Counter content

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02842 | FreqInxx: Offset

Data type: INTEGER_16

Index: 21733

d

= 54E5

h

Offset for digital frequency inputs

Using DI1(5) and DI2(6) as frequency inputs

Setting range

(min. value | unit | max. value)

-199.99

%

199.99

Subcodes

Lenze setting

Info

C02842/1

0.00 %

FreqIn12: Offset

C02842/2

0.00 %

FreqIn56: Offset

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100