12 position control/additive speed specification, Position control/additive speed specification, 5motor control (mctrl) – Lenze 8400 User Manual

Page 269

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

269

5

Motor control (MCTRL)

5.12

Position control/additive speed specification

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.12

Position control/additive speed specification

In the Lenze setting, the position control is only active with

TA "Table positioning"

.

Proceed as follows to open the dialog for parameterising the position control:

1. »Engineer« Go to the Project view and select the 8400 protec HighLine controller.
2. Select the Application parameters tab from the Workspace.
3. Go to the Overview dialog level and click the Motor control... button to change to the

Overviewmotor control... dialog level.

4. Click the Position control button in the displayed signal flow.

Parameter

Info

1

C00830/22

MCTRL: nSpeedSetValue_a

Speed setpoint

2

C00834/4

MCTRL: dnDeltaPos_p

Position difference (following error input)

3

C00834/5

MCTRL: dnPosSetValue_p

Absolute position setpoint

4

C00833/35

MCTRL: bDeltaPosOn

TRUE = Position difference is active as setpoint selection

5

C00254

Kp position controller

Gain for following error compensation

6

C00830/20

MCTRL: nPosCtrlPAdapt_a

Adaptation of the position controller gain

7

C00833/67

MCTRL: bPosDerivativeOn

TRUE = Setpoint for the speed controller is created from the position setpoint

8

C00830/21

MCTRL: nPosCtrlOutLimit_a

Limitation of the position controller output

9

C00833/27

MCTRL: bPosCtrlOn

TRUE = Position/angle control active