C00712

C00715

C00716

C00717

C00711/51

0: Not connected

LA_TabPos

: bFreeIn3

Input for binary user signal 3

C00711/52

0: Not connected

LA_TabPos

: bFreeIn4

Input for binary user signal 4

C00711/53

0: Not connected

LA_TabPos

: bFreeIn5

Input for binary user signal 5

C00711/54

0: Not connected

LA_TabPos

: bFreeIn6

Input for binary user signal 6

C00711/55

0: Not connected

LA_TabPos

: bFreeIn7

Input for binary user signal 7

C00711/56

0: Not connected

LA_TabPos

: bFreeIn8

Input for binary user signal 8

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00711 | LA_TabPos: Digital connection list

Data type: UNSIGNED_16

Index: 23864

d

= 5D38

h

Parameter | Name:

C00712 | LA_TabPos: phi connection list

Data type: UNSIGNED_16

Index: 23863

d

= 5D37

h

Connection parameters for "Table positioning" application: 32-bit inputs

• Selection of the 32-bit output signals for connection with the 32-bit input signals

• The selection list contains all 32-bit output signals which can be assigned to the 32-bit inputs mapped by the

subcodes.

Selection list
See

selection list - angle signals

Subcodes

Lenze setting

Info

C00712/1

0: Not connected

LA_TabPos

: dnPosProfilePosition

Input for selecting the target position in [increments]

C00712/2

0: Not connected

LA_TabPos

: dnFreeIn1

Input for 32-bit user signal 1

C00712/3

0: Not connected

LA_TabPos

: dnFreeIn2

Input for 32-bit user signal 2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00715 | LA_TabPos_Out: Analog signal list

Data type: UNSIGNED_16

Index: 23860

d

= 5D34

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00716 | LA_TabPos_Out: Digital signal list

Data type: UNSIGNED_16

Index: 23859

d

= 5D33

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00717 | LA_TabPos_Out: phi signal list

Data type: UNSIGNED_16

Index: 23858

d

= 5D32

h

This code is for device-internal use only and must not be written to by the user!