8basic drive functions (mck) – Lenze 8400 User Manual
Page 494
8
Basic drive functions (MCK)
8.6
Homing
494
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Mode 7: <_Rn_<_TP
Procedure:
1. Movement in negative direction with start profile data set.
2. Positive edge at bHomingMark activates search profile data set for further reference search.
3. Negative edge at bHomingMark enables home position detection.
4. Following edge of the touch probe sensor sets home position.
Touch probe
Pre-stop mark
Mode 7
<
Rn
<
TP
Offset path
Sequence profile (optional)
Start speed
Search speed
Profile speed
Lp
Inactive
Inactive
Inactive
Inactive
Active
Active
Ln
Active
Active
Active
Active
Active
Active
1
0