C01299 | mcki: status mckinterface, C01298/1, C01298/2 – Lenze 8400 User Manual

Page 1013: C01298/3, C01298/4, C01299, C01298, N be set in, 16 parameter reference

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1013

16

Parameter reference

16.2

Parameter list | C01298

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01298

C01299

Parameter | Name:

C01298 | MCK: Operating mode change with profile no.

Data type: UNSIGNED_8

Index: 23277

d

= 5AED

h

FB

L_MckCtrlInterface_1

: Assignment of an operating mode to a profile

Selection list

Info

0 No change

There will be no changed operating mode when the

profile is changed. Instead, the operating mode

requested "from outside" via the MCK control word

applies.

1 Follower

Change to the "Speed follower" mode

2 Homing

Change to the "Homing" mode

3 ManualJog

Change to the "Manual jog" mode

4 Positioning

Change to the "Positioning" mode

Subcodes

Lenze setting

Info

C01298/1

1: Follower

MCK operating mode at profile no. 0

• Selection of the operating mode for profile 0 at

L_MckCtrlInterface_1.

C01298/2

2: Homing

MCK operating mode at profile no. 1

• Selection of the operating mode for profile 1 at

L_MckCtrlInterface_1.

C01298/3

3: ManualJog

MCK operating mode at profile no. 2

• Selection of the operating mode for profile 2 at

L_MckCtrlInterface_1.

C01298/4

4: Positioning

MCK operating mode at profile no. 3...15

• Selection of the operating mode for profile 3 ... 15 at

L_MckCtrlInterface_1.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01299 | MCKI: Status MCKInterface

Data type: UNSIGNED_8

Index: 23276

d

= 5AEC

h

FB

L_MckCtrlInterface_1

: Status messages

Display area

(min. hex value | max. hex value)

0x00

0xFF

Value is bit-coded:

Info

Bit 0 InvalidOperationMode

Invalid operating mode selection

• "1" ≡ The selected operating mode is not

defined/invalid.

Bit 1 InvalidPosMode

Invalid positioning mode selection

• "1" ≡ The selected positioning mode is not

defined/invalid.

Bit 2 InvalidProfileNo

Invalid profile number selection

• "1" ≡ The selected profile number refers to a profile

data set that does not exist.

Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT