Parameter reference

16.2

Parameter list | C01501

1018

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01501

C01670

Parameter | Name:

C01501 | Resp. to communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring functions for the communication module
Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C01501/1

0: No Reaction

Resp. to MCI connection error

• Response to a communication error of the attached

communication module.

C01501/2

0: No Reaction

Resp. to MCI invalid module

• Response to an unplugged or incompatible

communication module

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01670 | L_ComparePhi 1-5: Function

Data type: UNSIGNED_8

Index: 22905

d

= 5979

h

Selection of comparison operation

• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.

Selection list

1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|

Subcodes

Lenze setting

Info

C01670/1

1: In1 = In2

L_ComparePhi_1

: Function

C01670/2

1: In1 = In2

L_ComparePhi_2

: Function

C01670/3

1: In1 = In2

L_ComparePhi_3

: Function

C01670/4

1: In1 = In2

L_ComparePhi_4

: Function

C01670/5

1: In1 = In2

L_ComparePhi_5

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising