C00080 | override point of field weakening, C00081 | rated motor power, C00082 | motor rotor resistance – Lenze 8400 User Manual

Page 759: C00083 | motor rotor time constant, C00084 | motor stator resistance, C00081, Rate, C00084, C00082, C00083

Advertising
background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

759

16

Parameter reference

16.2

Parameter list | C00080

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00080

C00081

C00082

C00083

C00084

Parameter | Name:

C00080 | Override point of field weakening

Data type: INTEGER_16

Index: 24495

d

= 5FAF

h

Offset of the override point of field weakening

• In the V/f characteristic control mode (

VFCplus

), the stall protection function or the max. permissible current in

the field weakening range can be adapted.

Setting range

(min. value | unit | max. value)

Lenze setting

-500

Hz

500 0 Hz

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00081 | Rated motor power

Data type: UNSIGNED_16

Index: 24494

d

= 5FAE

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.

Note:

It is mandatory to give the rated motor power for the sensorless vector control (

SLVC

) and the servo control (

SC

).

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

kW

500.00 11.00 kW

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00082 | Motor rotor resistance

Data type: UNSIGNED_32

Index: 24493

d

= 5FAD

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0

mOhm

200000 276 mOhm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00083 | Motor rotor time constant

Data type: UNSIGNED_16

Index: 24492

d

= 5FAC

h

Display of the rotor time constant of the motor

• This value is calculated from the rotor resistance and the rotor inductance (leakage and magnetising

inductance).

Display range

(min. value | unit | max. value)

0

ms

32767

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00084 | Motor stator resistance

Data type: UNSIGNED_32

Index: 24491

d

= 5FAB

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0

mOhm

200000 330 mOhm

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1